Prediction accuracy report

Accuracy Report: logS prediction

Table of contents

Experimental vs predicted logS

Distribution of experimental logS values

Statistical parameters

Test set parameters

Raw Data

Reproduce result using the CLI Parameters

History of accuracy result changes for LTS versions

Experimental vs predicted logS
Distribution of experimental logS values

Statistical parameters

  • RMSE: 1.16
  • Pearson correlation: 0.84
  • Ranged delta distribution
    • Δ < 0.5 : 42%
    • 0.5 < Δ < 1.0 : 28%
    • Δ > 1.0 : 29%

Test set parameters

Raw data

CLI Parameters

This report was generated using the logS predictor, version Fermium. You can use the cxcalc command line tool to reproduce the results above.

Example: evaluate -e logS -i true input.sdf

To read more about our CLI tool, click here. The command line tool is available for download within the JChem Suite.

History of accuracy result changes for LTS versions